Market researchClosing soon
Sources Sought Only - PIMC Fire Alarm Replacement Services
HEALTH AND HUMAN SERVICES, DEPARTMENT OF › INDIAN HEALTH SERVICE › PHOENIX AREA INDIAN HEALTH SVC
Response deadlineSep 2, 2026 1:00 PM EDT
View official notice on SAM.gov ↗ (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice.
Read the Data Disclaimer.
Key decision factors
- Response deadline
- Sep 2, 2026 1:00 PM EDT
- Posted
- Aug 27, 2026 12:00 AM EDT
- Notice type
- Sources Sought
- Set-aside
- Indian Small Business Economic Enterprise
- NAICS
- Not provided by SAM.gov
- PSC
- J012
- Place of performance
- Phoenix, Arizona
- Current status
- Closing soon
Notice details
- Official status
- Closing soon
- Normalized group
- Market research
- Notice ID
- 6487eb10865a43e9a5efdb821c6abee7
- Solicitation number
- IHS1530891
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Aug 28, 2026 5:16 PM EDT.
***SOURCES SOUGHT ONLY*** The Indian Health Service (IHS), Phoenix Indian Medical Center (PIMC), Phoenix, Arizona, is conducting market research to identify capable sources for the replacement and upgrade of the existing fire alarm control panel (FACP) and graphical user interface (GUI) system serving the PIMC hospital campus. The requirement includes removal and replacement of the existing fire alarm control panel with a NOTIFIER-compatible system or approved equal that is fully compatible with the existing fire alarm infrastructure and approximately 539 existing field devices in Building 233, including smoke/photo detectors, manual pull stations, duct and heat detectors, waterflow and supervisory switches, notification appliances, and water leak detection devices. Five additional campus buildings are also connected to the FACP located in Building 233. Existing field devices and loops will remain in place and are not intended to be replaced. The requirement also includes replacement of two existing annunciators; replacement of the existing GUI/workstation with the latest ONYXWorks GUI system or approved equal; required network hardware, power supplies, batteries, software licenses, and accessories; system programming and updated points lists; floor-plan graphics and device mapping; testing and commissioning; system cutover and phasing; training; and required closeout documentation. The system shall operate independently of the hospital LAN and shall not require internet connectivity, external data transmission, or cloud-based services. The contractor must demonstrate the capability and experience necessary to install, program, commission, and service a system of comparable size and complexity while maintaining compatibility with the existing NOTIFIER infrastructure. If proposing an equal solution, the respondent must clearly demonstrate how the proposed solution will provide full compatibility with the existing field devices, loops, system architecture, and required functionality without requiring replacement of the existing field devices and loops. All work shall comply with applicable fire/life-safety codes and the requirements identified in the Statement of Work. The anticipated period of performance is 100 days from issuance of the Notice to Proceed (NTP).
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free Account
Pursuit risk (separate from your match score)
Review before pursuing
We found a requirement that may limit who can compete. Review the solicitation details before proceeding.
Detected in
- Solicitation document“zations qualifications and ability to provide the requirement depicted above. 8. Documentation from manufacturer (i.e., correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.”
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.