Free Beta: Procurement discovery is free; verify every opportunity on SAM.gov. Source status
Market researchClosed

FY26: Artificial Intelligence Endoscopy Module

VETERANS AFFAIRS, DEPARTMENT OF › 248-NETWORK CONTRACT OFFICE 8 (36C248)

Response deadlineSep 18, 2026 12:00 PM EDT
View official notice on SAM.gov (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice. Read the Data Disclaimer.

Key decision factors

Response deadline
Sep 18, 2026 12:00 PM EDT
Posted
Sep 8, 2026 12:00 AM EDT
Notice type
Sources Sought
Set-aside
Not provided or not applicable
PSC
6515 — Medical and Surgical Instruments, Equipment, and Supplies
Place of performance
San Juan, Puerto Rico
Current status
Closed

Notice details

Official status
Closed
Normalized group
Market research
Notice ID
82d3e8fd4c0b4658ba0e21989805a2d4
Solicitation number
36C24826Q1222

Description

Displayed as sanitized plain text from SAM.gov. Retrieved Sep 9, 2026 10:23 PM EDT.

THIS IS A SOURCES SOUGHT NOTICE ONLY. It is neither a solicitation nor a Request for Quote (RFQ) and it does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. The Government will reimburse any costs associated with preparing a response to this notice. The purpose of this Sources Sought Notice is to conduct market research, identify potential qualified vendors, and determine their Small Business Administration (SBA) size classification under NAICS 334510 – Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard: 1,250 employees). The Department of Veterans Affairs, Network Contracting Office (NCO) 8, is seeking sources capable of providing a new and updated Medtronic GI Genius Intelligent Endoscopy Module for the VA Caribbean Healthcare System. The Government is considering trade?in options for the replacement of the Medtronic GI Genius Intelligent Endoscopy Module, CB17808?EU. The contemplated acquisition includes replacement, purchase, delivery, and training on the new equipment. NOTE: The following item includes equipment manufactured by Medtronic. We are requesting information for an EQUAL product with preference at this time for domestic products. The domestic product must meet or exceed the salient characteristics provided as follows: Model: GGM300-US Manufacturer: Medtronic Intelligent Endoscopy Module: The module is computer-aided polyp detection system of various sizes, shapes and morphologies powered by artificial intelligence. Enhanced visualization: The GI Genius endoscopy module empower physicians to detect colorectal polyps through enhanced visualization during the colonoscopy. Precision: Endoscopists with higher adenoma detection rates (ADR) during screening colonoscopy, more effectively protect their patients from colorectal cancer. Increase Adenoma Detection Rates (ADR): Module has been shown to increase ADR by up to 14.4%.2 Each 1% increase in ADR decreases the risk of interval cancer by 3%. Sensitivity rate: GI Genius module has a 99.7% sensitivity rate and less than 1% false positives. Field of View: 140° or 170° viewing angle Depth of field: upper range of 100 mm Endoscopy Video Processors Compatibility GI Genius Module 300 is compatible with VPs featuring HD-SDI (SMPTE 292M), 3G-SDI (SMPTE 424M), 6G/SDI (SMPTE ST2081) or 12G/SDI (SMPTE ST2082) output port and displays featuring HD-SDI (SMPTE 292M), 3G-SDI (SMPTE 424M), 6G-SDI (SMPTE ST2081) or 12G-SDI (SMPTE ST2082) input ports. GI Genius system is only compatible with the following VPs: Olympus CV-180 EXERA II; Olympus CV-190 EXERA III; Fujifilm VP-4450HD; Pentax EPK-i7000; Fujifilm VP-7000; Olympus CV-1500 EVIS X1; Pentax EPK-i8020c; Pentax EPK-i5500c. Concerns may respond by submitting a qualifications letter including the following information: Company Name Company Address Point of Contact Phone, Fax, and Email System for Award Management (SAM) Unique Entity Identifier (UEI) Code Capability Statement specific to the technical requirements and include product brochure, if possible. Provide evidence that your firm can provide the requested items, including past and/or current contracts for the same requirements, and any other compelling evidence to help the Government determine your company’s capabilities. To be eligible for an award, prospective offerors must be registered in the System for Award Management (SAM) at: www.sam.gov/content/home. Responses to this notice shall be submitted via email no later than 12:00 PM Eastern Standard Time on September 18, 2025. Telephone and facsimile responses will not be accepted. Please email your response to: Jessica.Kiser@va.gov. Email Subject Line: Sources Sought Notice-36C24826Q1222- AI Endoscopy Module for VACHS No further information is available at this time. The Government appreciates your interest and the time invest in preparing and submitting your response.

Attachments

1 attachment reported by SAM.gov

Files are hosted by SAM.gov. Open the official notice to review and download them.

View attachments on SAM.gov (opens in a new tab)

Contacts

Jessica Kiser
Primary
jessica.kiser@va.gov

Personalized relevance

Would this fit your company?

Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.

Create Free Account

Pursuit risk (separate from your match score)

Document analysis pending

Some solicitation documents have not been analyzed yet. Additional restrictions may still be present.

Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.