Free Beta: Procurement discovery is free; verify every opportunity on SAM.gov. Source status
Bid opportunityClosing soon

Sodium Iodide Detector for Thyroid Counting

HEALTH AND HUMAN SERVICES, DEPARTMENT OF › FOOD AND DRUG ADMINISTRATION › FDA Office of Acquisitions and Grants Services

Response deadlineAug 31, 2026 2:00 PM EDT
View official notice on SAM.gov (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice. Read the Data Disclaimer.

Key decision factors

Response deadline
Aug 31, 2026 2:00 PM EDT
Posted
Aug 25, 2026 12:00 AM EDT
Notice type
Combined Synopsis/Solicitation
Set-aside
Small Business Set Aside - Total
NAICS
334516
PSC
6630
Place of performance
Winchester, Massachusetts
Current status
Closing soon

Notice details

Official status
Closing soon
Normalized group
Bid opportunity
Notice ID
d3c5244a4a9a4cce939b61b0fb4802ef
Solicitation number
75F40126Q00375

Description

Displayed as sanitized plain text from SAM.gov. Retrieved Aug 26, 2026 5:17 PM EDT.

This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately. Solicitation No.: 75F40126Q00375 Contracting Activity: Food and Drug Administration (FDA) Office/Center: Office of the Commissioner (OC) Acquisition Type: Commercial Product Solicitation Type: Request for Quotation (RFQ) Contract Type: Firm-Fixed-Price Purchase Order Estimated Value: $20,000 Required Delivery: September 15, 2026 DELIVERABLE: 1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer Delivery Date: 9/15/2026 2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output Delivery Date: 09/15/2026 Salient Characteristics The equipment offered shall meet or exceed all requirements listed below. Detector Characteristics 3”X 3” NaI(Tl) LED Stabilized Scintillation Detector Energy Range 30 keV to 3 MeV Resolution >7% Available with generic efficiency characterization OPERATING HUMIDITY – 85% non-condensing OPERATING TEMPERATURE – -20 to +50 °C (-4 to 122 °F). Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer Diameter less than 3.5” Weight < 6 lbs Multi-Channel Digital Analyzer Characteristics Includes HVPS, Preamplifier and Digital MCA Gain Coarse Gain: x1, x2, x4, x8 software programmable Fine Gain: x1 – x5 software programmable Total Gain: Product of Fine Gain and Coarse Gain, x1 – x40 ADC: ADC 14-Bit 20 MHz Sampling ULD/LLD ULD: 0% to 100% of Full Scale software programmable LLD: 0% to 100% of Full Scale software programmable Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz Rise Time: 0.2 ?s – 5 ?s in 200 ns steps. Default: 1 ?s for NaI probe Flat Top: 0 to 3 ?s in 100 ns steps. Default: 1 ?s for NaI probe Digital Spectrum Stabilization Automatic Baseline Restore Automatic Fast Discriminator threshold Seamlessly compatible with Apex InVivo Software USB 2.0 and Ethernet 10/100BaseTX Output 14 pin and 8 pin PMT socket compatible Diameter less than 3.5” Weight < 6 lbs ACQUISITION MODES PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each Preset: ROI Counts (Integral), Real or Live Time timers Real and Live Time Resolution: 0.01 s Preset Time: 0 to >4 x 107 s Control: Internal or External Start/Stop control LTC accuracy: 5% (3% typical) up to 50 kcps MCS MCS Dwell range: 1 ?s to 999 seconds in 1 ?s steps Sweep range: 1 to 232 -1 Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies "Forever") MCS input selection: PHA ROI, external TTL or Fast Discriminator Dwell selection: internal or external MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each 8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel Integral Non-linearity: ±0.025% of full scale over the top 99% of the selected range Differential Non-linearity: ±1% over the top 99% of the range including the effects from integral non-linearity Gain Drift: <75 ppm/°C after 15 minutes of operation Incoming Count Rate (ICR): >250 K cps ICR if not limited by probe/detector Short Circuit Protection High Voltage Power Supply OUTPUT: 0-1300 V at 50 ?A max RIPPLE: 1 mV — ACCURACY: 3% Full Scale SETTING RESOLUTION: 14-bit (1/16 384) WARRANTY AND SUPPORT The Contractor shall provide a minimum 12-calendar-month warranty covering all parts and labor. The warranty period shall begin on the date of formal Government acceptance. Warranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system. Review the attached document for complete description of the requirement.

Attachments

1 attachment reported by SAM.gov

Files are hosted by SAM.gov. Open the official notice to review and download them.

View attachments on SAM.gov (opens in a new tab)

Contacts

Lilibeth Deato
Primary
lilibeth.deato@fda.hhs.gov
Phone: 3017960349

Personalized relevance

Would this fit your company?

Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.

Create Free Account

Pursuit risk (separate from your match score)

Document analysis pending

Some solicitation documents have not been analyzed yet. Additional restrictions may still be present.

Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.