Free Beta: Procurement discovery is free; verify every opportunity on SAM.gov. Source status
Bid opportunityClosed

Boiler Inspection and Repairs

HOMELAND SECURITY, DEPARTMENT OF › FEDERAL LAW ENFORCEMENT TRAINING CENTER › FLETC PROCUREMENT CHELTENHAM OFFICE

Response deadlineSep 11, 2026 12:00 PM EDT
View official notice on SAM.gov (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice. Read the Data Disclaimer.

Key decision factors

Response deadline
Sep 11, 2026 12:00 PM EDT
Posted
Sep 4, 2026 12:00 AM EDT
Notice type
Combined Synopsis/Solicitation
PSC
J042 — Maintenance, Repair and Rebuilding of Equipment: Fire Fighting, Rescue, and Safety Equipment; and Environmental Protection Equipment and Materials
Place of performance
Cheltenham, Maryland
Current status
Closed

Notice details

Official status
Closed
Normalized group
Bid opportunity
Notice ID
9bcdb292c772433d95ee254ad901624c
Solicitation number
70LCHE26QPFB00004

Description

Displayed as sanitized plain text from SAM.gov. Retrieved Sep 5, 2026 10:23 PM EDT.

The Contractor shall perform a comprehensive inspection of all 13 gas boilers and calibrate the associated gas sensors. The Contractor must troubleshoot any conditions found that affect the proper operation of the boilers. Bidders are responsible for verifying all site conditions and quantities prior to bid submission. The Contractor shall provide a complete inspection and troubleshooting service, which includes: Submitting a detailed assessment checklist noting all deficiencies. Providing a line-item cost estimate to correct any identified deficiencies. Ensuring the inspection covers, at a minimum: Mounting, Isolators, and Filter Components Burner and Gas Train Breeching and Combustion Air Boiler Inspection and Chemical Treatment Fan functionality Sight Glass, Water Piping, Gas Piping, and associated valves Electrical connections, including disconnect switch and safety circuits Control systems, firing sequences, and interlocks Safety controls, flame safeguards, and low water cutout Pressure and temperature gauges Testing of the safety relief valve Calibrating all gas sensors and ensuring they communicate correctly with the Building Automation System (BAS).

Attachments

5 attachments reported by SAM.gov

Files are hosted by SAM.gov. Open the official notice to review and download them.

View attachments on SAM.gov (opens in a new tab)

Contacts

Chris Dills
Primary
chris.d.dills@fletc.dhs.gov

Personalized relevance

Would this fit your company?

Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.

Create Free Account

Pursuit risk (separate from your match score)

No major pursuit restriction detected

We did not detect a major source or competition restriction in the information analyzed. This is not an eligibility determination.

Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.