Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer
COMMERCE, DEPARTMENT OF › NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY › DEPT OF COMMERCE NIST
Response deadlineSep 21, 2026 12:00 PM EDT
View official notice on SAM.gov ↗ (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice.
Read the Data Disclaimer.
Key decision factors
- Response deadline
- Sep 21, 2026 12:00 PM EDT
- Posted
- Sep 17, 2026 12:00 AM EDT
- Notice type
- Solicitation
- PSC
- 6630 — Chemical Analysis Instruments
- Place of performance
- Gaithersburg, Maryland
- Current status
- Closed
Notice details
- Official status
- Closed
- Normalized group
- Bid opportunity
- Notice ID
- c3d1218425364835b7b429d402a51245
- Solicitation number
- 1333ND26QNB640601
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Sep 18, 2026 10:23 PM EDT.
***Amendment 0001**** Amendment 0001 provides resposnes to questions received in response to the solicitation. Q.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system? A.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb. Q.2. What types of samples will be tested? A.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases. Q.3. What specific substances or compounds need to be detected or analyzed in these samples? If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly. A.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts. Q.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)? A.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel. There is not an extension to the solicitation as a result of this amendment. The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET. End of Amendment 0001 ******** See attached.
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free Account
Pursuit risk (separate from your match score)
Document analysis pending
Some solicitation documents have not been analyzed yet. Additional restrictions may still be present.
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.