Bid opportunityClosed
DOUBLE WALL INSULATED DUCTING
DEPT OF DEFENSE › DEPT OF THE ARMY › W6QM MICC-FT DRUM
Response deadlineSep 29, 2026 11:00 AM EDT
View official notice on SAM.gov (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice. Read the Data Disclaimer.
Key decision factors
- Response deadline
- Sep 29, 2026 11:00 AM EDT
- Posted
- Sep 21, 2026 12:00 AM EDT
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- Small Business Set Aside - Total
- PSC
- 4520 — Space and Water Heating Equipment
- Place of performance
- McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501, 74501
- Current status
- Closed
Notice details
- Official status
- Closed
- Normalized group
- Bid opportunity
- Notice ID
- 935547c9005b40848f8a202853b1e8c5
- Solicitation number
- W911S226U4509
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Sep 24, 2026 2:10 AM EDT.
Salient Characteristics for the Dual-Wall Insulated Aluminum Spiral Duct System: 1. Dual-Wall Spiral Pipe Part Code: 39230 Description: Straight dual-wall, insulated spiral duct pipe. Inside Diameter: 30 inches Outside Diameter: 34 inches Wall Thickness: 0.040 inches for both inner and outer walls. Material: Aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Spacers: Internal I-beam spacers every 8 inches to maintain duct separation. Quantity: 140 feet 2. 90-Degree Elbow Part Code: 3923090 Description: 90-degree bend for the duct system. Construction: 5-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 4 3. 45-Degree Elbow Part Code: 3923045 Description: 45-degree bend for the duct system. Construction: 3-piece gored elbow. Inside Diameter: 30 inches Outside Diameter: 34 inches Bend Radius: 45-inch centerline radius. Material: 0.040-inch aluminum. Insulation: 2-inch thick fiberglass with a density of 1.5 lbs/cu. ft. Quantity: 2 4. Reducing Lateral Cross Fitting Part Code: 3012523 Description: A cross-shaped fitting that reduces the main duct size and has two branches. Main Inlet/Outlet: Reduces from 30 inches to 28 inches. Branches: Two 12-inch diameter branches at a 45-degree angle. Material: 0.040-inch aluminum. Quantity: 1 5. Flange System for Main Pipe Part Code: 302406 Description: Connection system (AccuFlange) for joining the 30 x34 dual-wall pipe and elbows. Function: Must be factory-installed on pipe and elbow ends for proper alignment and connection. Material: Aluminum. Quantity: 41 6. Clamp for Connections Part Code: 34241 Description: 34-inch QuickDraw clamp to secure the outer flange connections. Sealing: Must have a built-in self-sealing rubber gasket to ensure an airtight seal. Material: Aluminum. Quantity: 21 7. Flange for 28-inch Port Part Code: 286G Description: 28-inch aluminum flange. Function: Must be factory-installed on the 28-inch outlet of the reducing cross fitting. Quantity: 1 8. Flange for 12-inch Ports Part Code: 126G Description: 12-inch aluminum flange. Function: Must be factory-installed on the two 12-inch branches of the reducing cross fitting. Quantity: 2
Attachments
No attachments were reported for this notice. MaroNest reflects only what the source data reports — review the official SAM.gov notice (opens in a new tab) to confirm whether related documents or amendments exist.
Contacts
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free AccountPursuit risk (separate from your match score)
No major pursuit restriction detected
We did not detect a major source or competition restriction in the information analyzed. This is not an eligibility determination.
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.