Market researchClosed
Automated Liquid Handling Platform
HEALTH AND HUMAN SERVICES, DEPARTMENT OF › FOOD AND DRUG ADMINISTRATION › FDA OFFICE OF ACQ GRANT SVCS
Response deadlineSep 11, 2026 2:00 PM EDT
View official notice on SAM.gov ↗ (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice.
Read the Data Disclaimer.
Key decision factors
- Response deadline
- Sep 11, 2026 2:00 PM EDT
- Posted
- Sep 9, 2026 12:00 AM EDT
- Notice type
- Sources Sought
- Set-aside
- No Set aside used
- PSC
- 6640 — Laboratory Equipment and Supplies
- Place of performance
- Silver Spring, Maryland
- Current status
- Closed
Notice details
- Official status
- Closed
- Normalized group
- Market research
- Notice ID
- ef9e452c93204e60a3b6aabc21c1da43
- Solicitation number
- CBER-2026-135922
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Sep 10, 2026 10:24 PM EDT.
The U.S. Food and Drug Administration requires one (1) newly manufactured benchtop automated liquid handling platform, including a dedicated Windows control computer, instrument control software, adaptors, attachments, installation, user training, technical documentation, a minimum 12-month manufacturer warranty, and ancillary preventative maintenance. The platform must fit and operate within a biosafety cabinet measuring 46 in. W x 24 in. D x 30 in. H that supports 120 lbs without disrupting enclosure airflow; perform serial dilutions across or down a plate using standard disposable tip heads; use interchangeable 96-channel or 384-channel pipetting heads with independent tip pickup capability; provide a minimum 15-position deck; dispense 0.1 to 200 microliters with accuracy and precision no worse than 5% deviation; be configurable for future shaking, heating, cooling, and filtration; support standard 96-well and 384-well microplates; and operate under ambient conditions of 5 to 40 degrees Celsius and 10 to 90 percent relative humidity, non-condensing. The system must include a controller and perpetual workstation-bound software capable of generating custom protocols. Delivery is required within 30 days of award to the FDA White Oak Campus in Silver Spring, Maryland, with installation completed within 90 days of delivery. Installation includes placement, leveling, electrical connections, computer/workstation setup, software installation, calibration, system verification, operational qualification testing, and installation qualification documentation. On-site operator training for up to three personnel is required. The Government has identified the Agilent Technologies Bravo Automated Liquid Handling Platform as a product that meets the requirement. The brand name is referenced for descriptive purposes only; equivalent items that meet all stated salient characteristics will be considered
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free Account
Pursuit risk (separate from your match score)
Review before pursuing
We found a requirement that may limit who can compete. Review the solicitation details before proceeding.
Detected in
- Solicitation document“if desired. The platform shall include a controller and software to generate custom protocols. The platform shall include a dedicated computer to control the machine. The platform shall be compatible with standard format”
- Solicitation document“support of the Government's obligations under the Buy American statute and RFO Part 25; and (2) to determine whether capable small business concerns, whether as manufacturer, OEM, authorized distributor, or reseller, exi”
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.