Bid opportunityClosing soon
Health and Human Services (HHS) - Wide Procurement of Biosafety Level 4 (BSL-4) Suits- Personal Protective Equipment
HEALTH AND HUMAN SERVICES, DEPARTMENT OF › NATIONAL INSTITUTES OF HEALTH › NATIONAL INSTITUTES OF HEALTH OLAO
Response deadlineAug 21, 2026 9:00 AM EDT
View official notice on SAM.gov ↗ (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice.
Read the Data Disclaimer.
Key decision factors
- Response deadline
- Aug 21, 2026 9:00 AM EDT
- Posted
- Aug 17, 2026 12:00 AM EDT
- Notice type
- Combined Synopsis/Solicitation
- Set-aside
- No Set aside used
- NAICS
- 339999
- PSC
- 6640
- Place of performance
- Latham, New York
- Current status
- Closing soon
Notice details
- Official status
- Closing soon
- Normalized group
- Bid opportunity
- Notice ID
- 7e902eb3fadb43a9b049242a9b209b2a
- Solicitation number
- R75N98026Q00738
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Aug 18, 2026 8:09 PM EDT.
The purpose of this acquisition is to obtain multiple models of BSL-4 Positive Pressure Suits for use at the National Institutes of Health (NIH) and the Centers for Disease Control and Prevention (CDC). The NIH Division of Logistics Services (DLS), through the Office of Logistics and Acquisition Operations (OLAO), OALM, NIH, intends to award a sole-source firm-fixedprice purchase order to Protective Industrial Products, Inc. (WX8TVG6ZFT64). The total estimated value of the purchase order, inclusive of all options, is $3,075,975 (see breakdown in the table below). The Government projects award no later than August 17, 2026. The planned period of performance is a base and two option years, commencing on August 17, 2026, through August 16, 2029, (if all option periods are exercised). The Office of Logistics and Acquisition Operations (OLAO) within OALM, NIH, anticipates awarding one purchase order for Biosafety Level 4 (BSL-4) positive pressure suits to support NIH and CDC personnel and researchers. The required procurement is for Honeywell brand protective suits designed specifically for life science personnel working within high-containment BSL-4 laboratory environments dealing with high-risk pathogens and deadly biological agents. Multiple models of BSL-4 positive pressure suits within the Honeywell product line will be procured under acquisition for mission critical functions. The requirement to procure the Honeywell brand is specific to this manufacturer, as no other vendor produces a functional equivalent that integrates seamlessly into the established laboratory infrastructure. The Honeywell suit is the only option among the marketplace that meets the salient characteristics (see table below) required for the specific research environments in NIH’s National Institute of National Institute of Allergy and Infectious Diseases (NIAID) and CDC. The following table lists the required safety criteria for BSL-4 positive pressure suits: Required Safety Criteria for BSL-4 Positive Pressure Suits Manufacturer must be able to meet demands of NIH facilities with need of ~200 per year Must be durable to withstand repeated use without defects Must demonstrate chemical compatibility with disinfectants used in the BSL-4 without degradation Suit ensemble must be offered in at least 5 unique and different sizes (S, M, L, XL, 2XL) Breathing airlines must be placed to accommodate human physiology Suit must not have noise levels that require hearing protection Breathing air flow rate must be 16-34 cubic feet per minute (CFM) Airline specifications must work with NIH BSL-4 facilities design (e.g., 80-100 psi maximum with 60 psi operational set point) Exhaust valves must be protected from direct chemical or other hazardous liquid splashes, must automatically seal upon disconnection from breathing air, and must have internal screens to protect from interference Suit gloves must attach to the suit using interface components to secure them to the suit and allow use of gloves currently in use at NIH BSL-4 facilities Suit must include internal HEPA filter on the breathing air line The color must be light so that splashes or contamination is easily visible on the surface Seams must be smooth to ensure effective decontamination with no excess fabric Temperature in the suit must not exceed 26C during continuous use for up to 5 hours Suit must have two different options for footwear, either with an attached outer boot or stocking feet that can be slipped into external shoes Must have shelf life of at least 5 years Suit must be designed in such a way that it can be tested by quantitative pressure decay test to ensure proper function and seal Visor or headpiece must have 300 degrees of transparency to ensure proper visibility of surroundings Suit must weigh less than or equal to10 lbs. to minimize stress to the user. Please see attached CSS document for full details.
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free Account
Pursuit risk (separate from your match score)
Strong pursuit warning
This notice contains language indicating a sole-source or otherwise restricted procurement. Review the cited evidence before investing time in a response.
Detected in
- Description“d the Centers for Disease Control and Prevention (CDC). The NIH Division of Logistics Services (DLS), through the Office of Logistics and Acquisition Operations (OLAO), OALM, NIH, intends to award a sole-source firm-fixe”
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.