Market researchClosing soon
6130--Uninterruptible Power Supply (UPS) for Pharmaceutical Refrigerators
VETERANS AFFAIRS, DEPARTMENT OF › 250-NETWORK CONTRACT OFFICE 10 (36C250)
Response deadlineOct 22, 2026 4:00 PM EDT · 5 days left
View official notice on SAM.gov ↗ (opens in a new tab)
Verify before acting. Users must verify deadlines, amendments, attachments, eligibility, and submission requirements on the official SAM.gov notice.
Read the Data Disclaimer.
Key decision factors
- Response deadline
- Oct 22, 2026 4:00 PM EDT · 5 days left
- Posted
- Oct 16, 2026 12:00 AM EDT
- Notice type
- Sources Sought
- Set-aside
- Not provided or not applicable
- PSC
- 6130 — Converters, Electrical, Nonrotating
- Place of performance
- Indianapolis, IN
- Current status
- Closing soon
Notice details
- Official status
- Closing soon
- Normalized group
- Market research
- Notice ID
- 52eb337459684492b8ad5fd845a24f56
- Solicitation number
- 36C25027Q0037
Description
Displayed as sanitized plain text from SAM.gov. Retrieved Oct 17, 2026 12:11 AM EDT.
SOURCE SOUGHT NOTICE - Uninterruptible Power Supply (UPS) for VA Medical Clinic This announcement requests information from industry to support market research and preliminary acquisition planning for the procurement described below. The purpose of this notice is to assess industry interest and identify potential sources with the capabilities and qualifications to meet the following requirements. This is not a solicitation for proposals. No contract will be awarded from this notice. No proposals are being requested or accepted with this notice. REQUIREMENT The agency is seeking information on domestic sources of supply for two types of Uninterruptible Power Supply (UPS) backups with salient characteristics described below: Type One Quantity 3 ea. Shall have at least 2000 Watts Output Shall have minimum surge capacity of 4,000 watts Made in America Must include at least 2 120V NEMA 5-20 duplex receptacles Dimensions cannot exceed be 91 H X 14 W X 10 D ±6 , in any direction Shall have single-phase 120 VAC, 60 Hz output Shall be capable of providing 88 hours of running time for a single half-size pharmaceutical refrigerator Shall be designed for operation in healthcare environments Automatic backup power activation transfer time shall be less than 20 milliseconds Shall be designed for indoor installation Must be capable of being wall mounted due to space limitations in the medication alcoves Shall provide a pure sine wave output suitable for medical-grade refrigeration, electronic controls, monitoring systems, and other sensitive healthcare equipment. Shall operate from a standard 120 VAC, 20-amp utility circuit and shall utilize a NEMA 5-20P connection or equivalent. Type Two Quantity 1 ea. Shall have at least 3000 Watts Output (Qty = 1) Shall have minimum surge capacity of 6,000 watts Made in America Must include at least 2 120V NEMA 5-20 duplex receptacles Dimensions cannot exceed 91 H X 55 W X 10 D ±6 any direction Shall have single-phase 120 VAC, 60 Hz output Shall be capable of providing 88 hours of running time for a single full-size pharmaceutical refrigerator Shall be designed for operation in healthcare environments Automatic backup power activation transfer time shall be less than 20 milliseconds Shall be designed for indoor installation Shall provide a pure sine wave output suitable for medical-grade refrigeration, electronic controls, monitoring systems, and other sensitive healthcare equipment. Shall operate from a standard 120 VAC, 20-amp utility circuit and shall utilize a NEMA 5-20P connection or equivalent. Interested parties who can provide the products described are requested to submit the following information: Company name, address and point of contact with phone number, SAM Unique Entity Identifier (UEI), Product information documenting salient characteristics, Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc., Place of manufacture, Any other pertinent company documentation. Note: All interested parties must be registered in SAM (System for Award Management) to be eligible for the award of a Government contract. Send submissions via email to Brian.Rosciszewski@VA.gov., reference 36C25027Q0037 is email subject. Firms that respond to this Sources Sought notice but do not provide ALL the requested information may not be considered by the Government when making acquisition decisions. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. Respondents may not be notified of the results of this notice; it is at the discretion of the Government to release any results. ** End of Sources Sought Notice **
Personalized relevance
Would this fit your company?
Create company profile information with a free account to see a deterministic, explainable relevance score. Matching does not determine eligibility or win probability.
Create Free Account
Pursuit risk (separate from your match score)
Document analysis pending
Some solicitation documents have not been analyzed yet. Additional restrictions may still be present.
Pursuit risk is evaluated separately from your match score above and never changes it. This is not a legal or eligibility determination — verify against the official SAM.gov notice and attachments.